govindex
Log in Sign up
Contract Record
Notice ID: 821defdf6cbe469b9a4e56d4ecff7256
Sources Sought Posted 2026-03-02 16:59:11.253+00 Due 2026-03-16 16:00:00+00

OCTO-FloX System

Agency
AGRICULTURE, DEPARTMENT OF
Notice ID
821defdf6cbe469b9a4e56d4ecff7256
Type
Sources Sought
Posted
2026-03-02 16:59:11.253+00
Award Amount
--
Description
Requirement for a rugged, field-ready hyperspectral spectrometer capable of sufficiently high spectral resolution to acquire solar-induced chlorophyll fluorescence and sequentially measuring six or more targets. Only minor follow-on work (firmware updates) are expected. Product must be equivalent to the OCTO-FloX produced by JB Hyperspectral Devices GmbH. Salient characteristics for Item 0001: The following are minimum specifications and performance criteria for the unit: • Spectral resolution fine enough to retrieve solar-induced chlorophyll fluorescence (SIF) from telluric and solar absorption features (< 1 nm FWHM). • Wavelength range wide enough to cover 500 – 900 nm to enable simultaneous acquisition of red SIF at 687 nm; far-red SIF at 760 nm; photochemical reflectance index (PRI) at 530 nm and 570 nm; normalized difference vegetation index (NDVI) and near-infrared reflectance of vegetation (NIRv) at 650 nm and 860 nm. • Capable of rapid acquisition across multiple (at least 6) vegetative targets in different plots or growth chambers using fixed fiber optics. • Capable of both hemispherical-conical or bi-hemispherical configurations, adjustable by user through removable cosine correctors designed for outdoor use. • Weatherproof (IP67 rated) to allow deployment of unit in variable outdoor environments. • Integrated thermal regulation to maintain spectrometer temperature consistently at 20 degrees Celsius. Intelligent temperature management modes for power saving. Heatingo for cold conditions. • System operational temperature range from -10 to 50 degrees Celsius.• Automatic optimization of integration time to maximize spectrometer dynamic range across 0-2000 PPFD. • Correction for dark current and detector nonlinearity. • Wavelength calibration and optimization of spectral shift. • Radiometric calibration for both bare fiber and cosine corrected fiber configurations. Salient characteristics for Item 0002 – JB COS Cosine Receptor for the measurement of solar irradiance. Must be equivalent to the JB COS produced by JB Hyperspectral. Salient Characteristics for Item 0002: • Must be 100 percent compatible with the other item(s) described in this notice (see Item 0001). • Cosine error of < 10% at 80 degrees • Spectral range of 400 nm - 1000 nm

Basic Information

Notice ID
821defdf6cbe469b9a4e56d4ecff7256
Solicitation #
1163769
Type
Sources Sought
Base Type
Sources Sought
Posted Date
2026-03-02 16:59:11.253+00
Response Due
2026-03-16 16:00:00+00
Archive Date
2026-03-31 00:00:00+00
Archive Type
auto15
Active
Yes

Agency

Department
AGRICULTURE, DEPARTMENT OF
Sub-Tier
AGRICULTURAL RESEARCH SERVICE
Office
USDA ARS AFM APD
CGAC
012
FPDS Code
12H2
AAC Code
1232SA

Award

Awardee
--
Award Amount
--
Award Number
--
Award Date
--

Classification

NAICS Code
334516
Classification Code
6640
Set-Aside
--
Set-Aside Code
--

Place of Performance

Street
--
City
Beltsville
State
MD
ZIP
20705
Country
USA

Organization

Type
OFFICE
City
BELTSVILLE
State
MD
ZIP
20705
Country
USA

Secondary Contact

Name
--
Title
--
Email
--
Phone
--
Fax
--